Description
The upper boiler door contains flue passages with flame tubes. The lower door contains the pellet combustion chamber with an additional water jacket. Thus, the combustion gases pass through three sections and achieve maximum combustion efficiency and high performance.
The set includes a pellet hopper, whose conveyor screw ensures automatic pellet feeding.
Pellet ignition takes place automatically by means of an electric igniter.
For complete and efficient pellet combustion, a forced-draft fan is used, which always ensures a sufficient amount of combustion air.
The flue gases are led out of the boiler by means of a flue gas fan, which helps prevent possible backburning.
Boiler operation is controlled by automation, whose input data and settings can be entered from the control panel located on the top of the boiler to ensure the parameters required for quality combustion.
Manufacturer: Šukom DOO, Serbia